Ambient Air Quality Monitoring System

Engineering & Environmental Solutions has independently developed this system through years of research and development experience in both domestic and international environmental and industrial monitoring applications.

It offers a wide detection range for parameters such as PM₁₀, PM₂.₅, SO₂, NO₂, O₂, CO, H₂S, and more.

FEATURES

  • Monitors multiple air pollutants
  • Supports GSM / Wi-Fi / LAN connectivity
  • Fully customizable to meet specific user requirements

Technical Specifications

Dimension 300X400X150mm
Materials Powder Coated MS
Ingress protection IP67
Ambient Temperature Range -20°C to 60°C
Battery Lithium-lon
Display Size 3.5 or 7inch
Communication Channel GSM/Wi-Fi/LAN
Sensor Specifications
Parameter Principle Detection Range Resolution Voltage Output Response Time
PM2.5 Light Scattering 0-500 ug/m3 1 ug/m3 N/A N/A
PM10 Light Scattering 0-1,000 ug/m3 1 ug/m3 N/A N/A
O2 Electrochemical 0-10 ppm 0.1 ppm (2-0)V ≤120s
SO2 Electrochemical 0-20 ppm 0.1 ppm (0.6-3)V ≤30s
NO2 Electrochemical 0-200 ppm 0.1 ppm (2-0)V ≤30s
CO Electrochemical 0-1,000 ppm 1 ppm (0.6-3)V ≤30s
H2S Electrochemical 0-100 ppm 1 ppm (0.6-3)V ≤30s
NH3 Electrochemical 0-100 ppm 1 ppm (0.6-3)V ≤150s
CO2 Electrochemical 400-500 ppm 1 ppm N/A N/A
O3 Electrochemical 0-10 ppm 0.1 ppm (2-0)V ≤120s
VOC Electrochemical 0-100 ppm 0.1 ppm (0.6-3)V ≤120s
H2 Electrochemical 0-1000 ppm 1 ppm (0.6-3)V ≤120s
Cl2 Electrochemical 0-20 ppm 0.1 ppm (2-0)V ≤60s
HCL Electrochemical 0-10 ppm 0.1 ppm (2-0)V ≤60s
HF Electrochemical 0-10 ppm 0.1 ppm (2-0)V ≤60s
Humidity Electrochemical 0-100 % Accuracy ±3% N/A N/A
Temp. Electrochemical -10 to 50ºC Accuracy ±0.3ºC N/A N/A