UV300 Online Water Analyzer

The UV300 is an economical online water analyzer designed to monitor one or two specific parameters. Utilizing reliable UV-visible spectroscopic technology, it measures organic matter, nitrate, color, and PAH. It can also be equipped with an optional colorimetric module for parameters such as PO₄, Cl₂, NO₂, Fe, and Al, along with a laser-diode turbidity sensor.

Additionally, it supports external probes for pH, ORP, dissolved oxygen, and conductivity measurements. The system features an automatic acid-cleaning mechanism and a durable xenon lamp to ensure minimal maintenance requirements. A web-based interface allows for easy remote operation and troubleshooting, enhancing overall usability and efficiency.

Technical Specifications

Online water analyzer, UV300 - Parameter specification
Parameter Standard range
Other ranges on request
Typical Repeatability
For low values (<10% FS)
Accuracy
On standard solution
UV254 0-200 Abs/m
0-600 Abs/m
0-2000 Abs/m
+/- 0.05 Abs/m
+/- 0.15 Abs/m
+/- 0.5 Abs/m
+/- 2%
COD by UV correlation 0-100 mg/l COD
0-2000 mg/l COD
0-20,000 mg/l COD
+/-0.05 mg/l COD
+/- 1 mg/l COD
+/- 10 mg/l COD
+/- 2%
BOD by UV correlation 0-100 mg/l BOD
0-1000 mg/l BOD
0-10,000 mg/l BOD
+/-0.05 mg/l BOD
+/- 0.5 mg/l BOD
+/- 5 mg/l BOD
+/- 2%
TOC by UV correlation 0-100 mg/l TOC
0-100 mg/l TOC
0-10,000 mg/l TOC
+/-0.05 mg/l TOC
+/- 0.5 mg/l TOC
+/- 5 mg/l TOC
+/- 2%
Nitrate 0-100 mg/l NO3 +/- 0.1 mg/l NO3 +/- 2%
Colour 0-100 Pt/Co
0-1000 Pt/Co
+/- 1 Pt/Co
+/- 2 Pt/Co
+/- 2%
PAH (aromatics) 0-10 mg/l C6H6 +/- 0.01 mg/l C6H6 +/- 2%
Chlorophyll A 0-100 µg/l ChlA +/- 1 µg/l ChlA +/- 2%
Oil in Water 0-100 ppm OIW
0-1000 ppm OIW
+/- 0.1 ppm OIW
+/- 1 ppm OIW
+/- 2%
Phosphate (PO4) 0-2 mg/l P-PO4
0-20 mg/l P-PO4
+/- 0.01 mg/l P-PO4
+/- 0.1 mg/l P-PO4
+/- 2%
Chlorine 0-5 mg/l Cl2 +/- 0.05 mg/l Cl2 +/- 2%
Nitrite 0-5 mg/l NO2 +/- 0.1 mg/l NO2 +/- 2%
Nitrite 0-5 mg/l NO2 +/- 0.1 mg/l NO2 +/- 2%
Aluminium 0 - 500 ppb Al +/- 10 ppb Al +/- 2%
Iron 0-2 mg/l Fe +/- 0.02 mg/l Fe +/- 2%
Silica 0-20 mg/l SiO2 +/- 0.1 mg/l SiO2 +/- 2%
Cr VI 0-2 mg/l Cr VI +/- 0.04 mg/l Cr VI +/- 2%
Turbidity
(TSS by correlation)
0-10 NTU
0-100 NTU
0-1000 NTU
+/- 0.01 NTU
+/- 0.1 NTU
+/- 1 NTU
+/- 2%
pH 0-14 pH +/- 0.01 pH +/- 2%
ORP +/- 2000 mV +/- 1 mV +/- 2%
Dissolved Oxygen (DO) 0-25 mg/l O2 +/- 0.1 mg/l O2 +/- 2%
Conductivity 0-2000 µS +/- 1 µS +/- 2%
External turbidity
(TSS by correlation)
0-4 NTU
0-40 NTU
  +/- 2%
+/- 2%
External TSS 0-1500 mg/l
0-30000 mg/l
+/- 1% of reading or +/- 2 mg/l TSS
+/- 1% of reading or +/- 2 mg/l TSS
+/- 2%
+/- 2%
Temperature 0-80 °C +/- 0.1°C +/- 2%
Online water analyzer, UV300 - General specification
Sample flow Recommended: 0 - 5 l/min
Sample pressure 0 - 4 Bar (0 - 1 Bar with sampling peristaltic pump)
Sample temperature 0 - 80 °C
Wet parts material Quartz, Polypropylene, Polyethylene, FPM (viton), PMMA
Measuring time 5 sec (except PO4, NO2, Fe, Cr(VI) : 3mn /, Cl2, Al : 2mn / SiO2 : 6 min)
Measurement interval 1 min to 720 min (If measuring time compatible)
Physicochemical parameters may be continuous
Memory 5000 lines of measurements (up to 16 channels) with date and time
Consumption Cleaning solution (5% sulfuric acid): 220 ml/day
Reagent per measurement : Al : 0.5ml /
Cl2, PO4, Fe, NO2, Cr(VI) : 0.6 ml / Sio2 : 1.2 ml
Maintenance interval Recommended: 6 months to 1 year (except for refilling)
Power supply 90 - 264 VAC 50/60 Hz 40 VA - 12v DC 3A maxi
Screen Colour TFT LCD 320x240 pixels with LED backlight
Communication RS232, Modbus or HTTP/Web interface, compatible with Windows7, with Internet Explorer version 9, Nexus 7 tablet under Android with Opera version 12.10, Apple I-phone 4S with Safari

RS485 for external probes (DO, TSS)
USB
WI-FI (IEEE802.11B) optional
Ethernet (IEEE802.3) optional
Certifications CE, EN 61010-1, EN 61326
Enclosure Stainless steel with epoxy coating, IP65, wall mounting brackets
Dimensions 420 x 360 x 200 mm
Weight 15 to 20 kg depending on the configuration