Continuous Emission Monitoring System

Engineered to precisely monitor a broad spectrum of pollutants such as PM, HCl, HF, NH₃, SOx, NOx, CO, O₂, CO₂, and VOCs, the system features an integrated remote calibration mechanism. Our CEMS guarantees adherence to environmental standards while supporting clean and sustainable operations.

CPCB Certified Technology

  • Monitors air particulate emissions
  • Delivers high accuracy with remote calibration capability
  • Includes dashboard configuration, control, and data logging features

Technical Specifications

Parameters measured SPM, SOx, NOx, CO, CO2, O2
Working temperature -20℃ to 40℃
Storage temperature -40℃ to 60℃
Ambient temperature Range -20°C to 60°C
Sensor Specifications
Parameter Technology Range Operating Temp. Resolution
SPM Tribo Opacity 0-1000 mg/Nm3
0-800 mg/Nm3
10-500°C 0.1 mg/Nm3
SOx NDIR 0-1000 PPM 0-45°C 1 PPM
NO NDIR 0-1000 PPM 0-45°C 1 PPM
CO NDIR 0-1000 PPM 10-45°C 1 PPM
CO2 NDIR 0-5000 PPM 0-45°C 1 PPM
O2 NDIR 0-20% 0-45°C 0.01%
Power Source
Power Supply (Main Board) 220-250 Volts
Cooler Voltage 110/220V AC
Frequency -50 Hz
Watt 80-100W
Sox Compressor 220 Volts

Technology NDIR

Performance Specification
Measurement SOx, NO, CO, CO2, O2
Precision ±2%FS
Repeatability ±1%FS
Stability <±2%FS/24h
Life span 3 years (in air)
Working Parameters
Working temperature 0-50°C
Relative humidity 0-90C
Sampling gas pressure ≤101kPa
Sampling Gas flow rate 0.7-1.2 L/min

SPM

Performance Specification
Measurement Solid Particles
Particulate Size 0.3 um or larger
Range 0.1 mg/m3 to 1kg/m3
Ambient Condition
Temperature -20 to +45°C
Humidity 95% RH (non-condensing)
Power Supply 115 VAC or 230 VAC or 24 VDC
Power Consumption 8W AC models, 3W 24 VDC mode